Affinity Chromatography
Affinity Chromatography
Affinity chromatography is a chromatographic method of separating biochemical mixtures, based on a highly specific biologic interaction such as that between antigen and antibody, enzyme and substrate, or receptor and ligand. Affinity chromatography combines the size fractionation capability of gel permeation chromatography with the ability to design a stationary phase that reversibly binds to a known subset of molecules. {mosgoogle left} Applications of Affinity ChromatographyAffinity chromatography can be used to: - Purify and concentrate a molecule from a mixture into a buffering solution
- Reduce the amount of a molecule in a mixture
- Discern what biological compounds bind to a particular molecule, such as drugs
Principle of Affinity ChromatographyUsually the starting point is an undefined heterogeneous group of molecules in solution, such as a cell lysate, growth medium or blood serum. The molecule of interest will have a well known and defined property which can be exploited during the affinity purification process. The process itself can be thought of as an entrapment, with the target molecule becoming trapped on a solid or stationary phase or medium. The other molecules in solution will not become trapped as they do not possess this property. The solid medium can then be removed from the mixture, washed and the target molecule released from the entrapment in a process known as elution. Batch and column setupsBinding to the solid phase may be achieved by column chromatography, whereby the solid medium is packed onto a chromatography column, the initial mixture run through the column to allow binding, a wash buffer run through the column and the elution buffer subsequently applied to the column and collected. These steps are usually done at ambient pressure (as opposed to HPLC or FPLC).
Alternatively binding may be achieved using a batch treatment, by adding the initial mixture to the solid phase in a vessel, mixing, separating the solid phase (by centrifugation for example), removing the liquid phase, washing, re-centrifuging, adding the elution buffer, re-centrifuging and removing the eluate.
Sometimes a hybrid method is employed, the binding is done by the batch method, then the solid phase with the target molecule bound is packed onto a column and washing and elution are done on the column.
A third method, expanded bed adsorption, which combines the advantages of the two methods mentioned above, has also been developed. The solid phase particles are placed in a column where liquid phase is pumped in from the bottom and exits at the top. The gravity of the particles ensure that the solid phase does not exit the column with the liquid phase.